Seitenansicht 69
6-2
MiniScan MS-320X Integration Guide
Note: If after performing these checks the symbol still does not scan,
contact your distributor or call the Symbol Support Center. See page
xiii for the telephone number.
Scanner cannot read the
bar code
Interface/power cables are loose. Re-connect loose cables.
Scanner is not programmed for
the correct bar code type.
Make sure the scanner is
programmed to read the type of bar
code to be scanned.
Try scanning other bar code(s) and
other bar code types.
Incorrect communication
parameters.
Set the correct communication
parameters (baud rate, parity, stop
bits, etc.)
Bar code symbol is unreadable. Check the symbol to make sure it is
not defaced. Try scanning similar
symbols of the same code type.
Inappropriately hot environment. Remove the scanner from the hot
environment, and allow it to cool
down.
Laser activates, followed by
a beep sequence.
Beeper is configured. Refer to Table 1-1 on page 1-8 for
beeper indication descriptions.
Scanner configured to USB
host and does not scan
(MS-3207 only).
Incorrect trigger mode selected. Unplug scanner from USB host.
Present Continuous Scan Mode bar
code and plug unit in. Upon power
up the MS-3207 scans briefly,
decodes, and switches to
continuous trigger mode.
Problem Possible Cause Possible Solutions