Code 39 Check Digit Verification
Parameter # 30h
When this feature is enabled, the scanner checks the integrity of all Code 39 symbols to
verify that the data complies with specified check digit algorithm. Only those Code 39
symbols which include a modulo 43 check digit are decoded.
Enable Code 39 Check Digit
(01h)
*Disable Code 39 Check Digit
(00h)